Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Original Article


Article page

41-49


Authors Details

Santanu Das*, Kiran Kumar L


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1243

PDF Downloaded: 1019


Comparative study of intraocular pressure measured by non-contact, rebound and goldmann applanation tonometer and their correlation with corneal thickness and true IOP in a general population


Original Article

Author Details : Santanu Das*, Kiran Kumar L

Volume : 6, Issue : 1, Year : 2020

Article Page : 41-49

https://doi.org/10.18231/j.ijceo.2020.010



Suggest article by email

Get Permission

Abstract

Aim: To compare the Intraocular Pressure (IOP) measured by Non-contact tonometer (NCT), Rebound
tonometer (RBT) and Goldmann Applanation tonometer (GAT) and their correlation with central corneal
thickness (CCT) and true IOP.
Reliability of each tonometer.
Materials and Methods: 500 random patients aged 18 years and above were taken up for the study.
Patients with anterior and posterior segment pathologies like corneal ulcer, leukoma, staphyloma, corneal
lacerations, ectatic corneal conditions, corneal dystrophies, oedema, perforations, acute angle closure
glaucoma, retinal detachments, vitreous haemorrhage and unwilling patients were excluded from the study.
IOP was recorded using NCT, RBT and GAT after assessing the patient’s visual acuity. Following IOP
measurement, central corneal thickness (CCT) of each patient was measured using pachymetry. All the
data were collected and tabulated for statistical analysis to obtain results.
Results: The mean CCT in males was 0.5350 mm and in females 0.5340 mm respectively. The mean
IOP measured by NCT is 16.43 mm hg whereas the mean IOP measured by GAT is 15.43 mm hg. IOP
measured by NCT is significantly higher than the IOP measured by GAT (p<0> RBT are compared NCT values are significantly higher than that of RBT(p<0> RBT IOP 15.83 mm hg is higher than the mean GAT IOP of 15.42 mm hg the values are not statistically
significant. When correlated with CCT all the tonometers showed significant correlation with GAT showing
the strongest correlation. NCT overestimates IOP in normal, thin and thicker corneas when compared
to GAT and are statistically significant. RBT also overestimates in the normal and thick corneas when
compared to GAT but their values are much closer to GAT values in thinner corneas. The IOP measured
by all the 3 tonometers correlated with corrected IOP with NCT showing the best correlation followed by
GAT.
Conclusion: From the present study we can conclude that IOP measured by NCT and RBT is higher
than GAT. NCT values are significantly higher than GAT values in thin and normal corneas whereas it
overestimates more in thicker corneas. RBT values are significantly higher than that of GAT in normal and
thick corneas. So, it is always advisable to measure the corrected IOP for each patient after considering the
CCT.

Keywords: Central corneal thickness, Goldmann applanation tonometer, Intraocular pressure, Non-contact tonometer, Rebound tonometer, True IOP.


How to cite : Das S , Kiran Kumar L, Comparative study of intraocular pressure measured by non-contact, rebound and goldmann applanation tonometer and their correlation with corneal thickness and true IOP in a general population. Indian J Clin Exp Ophthalmol 2020;6(1):41-49

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.