Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

  • Article highlights
  • Article tables
  • Article images

Article statistics

Viewed: 409

PDF Downloaded: 166


Get Permission Mukkamala, Mathukumalli, Undrakonda, and Pakalapati: A study of contrast sensitivity in eyes with hydrophobic and hydrophilic acrylic foldable posterior chamber intraocular lens


Introduction

Methods of cataract surgery have progressed from intracapsular cataract extraction (ICCE) to phacoemulsification, enabling intraocular lens implantation through small, suture less incisions. The use of foldable optic structures allow larger optical zones, reducing glare and improving overall outcomes. Even after a successful cataract surgery with intraocular Lens (IOL) implantation and satisfactory refractive results, patients frequently express concerns about the quality of their vision.

Contrast sensitivity (CS) plays a crucial role in visual quality, and it can decline after cataract surgery and intraocular lens (IOL) implantation. The optical design, dimensions, and spectral transmission characteristics of the IOL are factors that can affect contrast sensitivity.1

Contrast refers to the extent of black-to-white variation in an object or target. The contrast threshold represents the minimum contrast needed for clear object perception, while contrast sensitivity (CS) is the capacity to discern crisp and distinct outlines of minute objects.2, 3

While a patient may have 6/6 visual acuity, there can be a reduction in contrast sensitivity. Interestingly, the psychological impact of this loss in contrast sensitivity can sometimes be more distressing than the decline in visual acuity alone.4

Moreover, contrast sensitivity tends to decline earlier in the progression of ocular pathologies, even when visual acuity remains unimpaired. Visual acuity, in such cases, often underestimates the initiation and/or extent of visual impairment.5

The reduction in contrast sensitivity can impact everyday tasks like driving, reading, walking, using computers, and recognizing faces, thereby diminishing the overall quality of life.6, 7

While Snellen's chart measures visual acuity with high contrast, real-world scenarios may lead to visual impairment caused by decreased contrast sensitivity. In low-contrast conditions, both visual acuity and overall vision quality may decline. Contrast sensitivity is acknowledged as a superior predictor of visual acuity, offering insights beyond what visual acuity alone can provide.8

Evaluating contrast sensitivity serves as a valuable addition to standard visual acuity tests and should be incorporated into the regular optometric examination, even for patients with normal vision.9, 10, 11

The Pelli Robson chart, a widely adopted contrast sensitivity test, is known for its speed, repeatability, and reliability. This test is straightforward to administer, and in employing the psychophysics of letter recognition with printed letters of consistent size but varying contrast levels. Its proven reliability, effectiveness, and seamless integration into routine optometric assessments have been validated.12, 13

This is an analytical observational study to compare the effect of Hydrophilic and Hydrophobic Posterior Chamber Intraocular lens (IOL) on contrast sensitivity function in patients following an uneventful phacoemulsification surgery.

Materials and Methods

The initiation of the study was preceded by obtaining permission from higher authorities and clearance from the Institutional Ethics Committee. Conducted over a period of six months, from June 2023 to November 2023, this observational study prospectively observed patients who underwent uncomplicated phacoemulsification with posterior chamber intraocular lens implantation at the Department of Ophthalmology, Alluri Sitaramaraju Academy of Medical Sciences, Eluru, Andhra Pradesh.

A total of 50 patients meeting the inclusion and exclusion criteria underwent uneventful Phacoemulsification surgery were divided into two groups of 25 patients each.

Group A underwent Phacoemulsification with Foldable Hydrophilic Aspheric PCIOL implantation (Acryfold, Appasamy Associates).

Group B underwent Phacoemulsification with Foldable Hydrophobic Aspheric PCIOL implantation (SupraPhob, Appasamy Associates).

Patients having visually significant nuclear cataract up to NO3 NC3 according to LOCS III (Lens opacities classification classification system III) who underwent uneventful phacoemulsification surgery with foldable posterior chamber Intraocular lens in the bag and had postoperative vision better than or equal to 6/9 were included in the study.

Following were excluded from the study

  1. Patients with nuclear cataract greater than NO3 NC3, cortical and Posterior sub-capsular cataract.

  2. Patients with uncontrolled diabetes mellitus.

  3. Patients having degenerative conditions of Macula e g ARMD.

  4. Patients having any other ocular pathologies which will affect the contrast sensitivity function.

  5. Patients with history of previous ocular surgery other than cataract.

  6. Complicated cataract surgeries like associated vitreous loss, Posterior capsular rent, other than in the bag intraocular lens implantation.

Patients meeting the inclusion and exclusion criteria were examined preoperatively. The assessments included visual acuity was measured in LogMAR values using Snellen's test types and the evaluation of contrast sensitivity function was measured with Pelli-Robson’s contrast sensitivity chart, Corneal curvature (K1, K2) readings were measured with Autorefractor/keratometer, Intraocular Pressure measurement was measured with Goldmann Applanation Tonometer, Anterior segment evaluation was done with slit lamp biomicroscope, Dilated Fundus examination was done with Slit-lamp lenses, Axial length calculation and Intraocular power calculation was done by A scan. Postoperatively patients were evaluated for their Uncorrected visual acuity (UCVA), Best-corrected visual acuity (BCVA) and Contrast sensitivity function test using Pelli-Robson contrast sensitivity chart under Photopic luminance conditions with best spectacle correction at 12th week and assigned a score, with the scoring ranges from 0 to 2, where a score of 2.0 indicates normal contrast sensitivity at 100%. Scores below 1.5 (75%) are indicative of visual impairment, and a score below 1.0 (50%) signifies visual disability.

Statistical analysis

Microsoft Excel and IBM Statistical Package for the Social Sciences (SPSS) version 20 were employed for data analysis. Numerical data was presented as Mean and Standard Deviation. Intergroup comparisons for normally distributed data were conducted using the independent sample t-test, while intragroup comparisons before and after cataract surgery utilised the paired t-test. A P-value less than 0.05 was deemed statistically significant.

Results

A total of 50 patients who underwent uneventful phacoemulsification surgery with foldable IOL in the bag had a postoperative vision better than or equal to 6/9 were enrolled in our study, of whom 25 patients received hydrophobic intraocular lens and other 25 patients received hydrophilic intraocular lens. The majority of individuals undergoing phacoemulsification surgery were in the age group of 51 to 60 years (56%), with 26% of patients aged 50 or below. Females accounted for 52% of the cases, and 62% of the surgeries were performed on the right eye. (Table 1).

Table 1

Distribution of patients

Parameters

Hydrophobic IOL Group

Percentage (%)

Hydrophilic IOL Group

Percentage (%)

Age group

</= 50 years

6

24%

7

28%

51 - 60 years

15

60%

13

52%

61 - 70 years

4

16%

5

20%

> 70 years

0

0

Gender

Male

15

60%

9

36%

Female

10

40%

16

64%

Eye

Right

12

48%

19

76%

Left

13

52%

6

24%

The Mean Preoperative Best corrected visual acuity (BCVA) in the Hydrophobic group was 0.656 ± 0.208 and in Hydrophilic group it was 0.696 ± 0.203 measured in LogMAR, whereas Postoperative BCVA it was 0.184 ± 0.114 for Hydrophobic group and 0.196 ± 0.130 for the Hydrophilic group (Table 2).

Table 2

Mean visual acuity in patients before and after cataract surgery with the intraocular lenses

Best Corrected Visual Acuity (BCVA) in LogMAR (Logarithm of the Minimum Angle of Resolution)

Mean ± Standard Deviation

P Value

Hydrophobic IOL Group

Preoperative

0.656 ± 0.208

< 0.01

Postoperative

0.184 ± 0.114

Hydrophilic IOL group

Preoperative

0.696 ± 0.203

< 0.01

Postoperative

0.196 ± 0.130

Table 3 depicted; Mean Contrast sensitivity function postoperatively (1.997± 0.01) to be statistically significant (P value <0.01) to the preoperative contrast sensitivity (1.556 ± 0.16), signifying there was significant improvement in the Contrast sensitivity function post cataract surgery with Intraocular lens implantation (Figure 1). Paired t-test was done to analyse the data before and after cataract surgery.

Table 3

Contrast sensitivity function in both the groups before and after Phacoemulsification surgery with intraocular lens implantation

Contrast sensitivity function

Mean ± Standard Deviation (95% Confidence interval)

P Value

Preoperative

1.556 ± 0.16 (1.516 – 1.596)

<0.01

Postoperative

1.997 ± 0.01 (1.967 – 2.027)

Figure 1

Contrast sensitivity function before and after cataract surgery

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/619b310d-7b4e-48cf-ab7a-de47b2c7b0fe/image/d28b55dc-ba58-48d6-afb0-a78ed4bec515-uimage.png

Postoperative contrast sensitivity function in patients who received Hydrophobic (2.018 ± 0.12) or Hydrophilic (1.976 ± 0.12) intraocular lens was statistically significant (P value <0.01) to their preoperative contrast sensitivity values, which were 1.586 ± 0.15 and 1.526 ± 0.18 respectively (Table 4), (Figure 2, Figure 3). Paired t-test was done to analyse the data before and after cataract surgery.

Table 4

Contrast sensitivity function before and after cataract surgery with intraocular lens implantation

Contrast Sensitivity Function

Mean ± Standard Deviation (95% Confidence Interval)

P Value

Hydrophobic IOL Group

Preoperative

1.586 ± 0.15 (1.526 – 1.646)

< 0.01

Postoperative

2.018 ± 0.12 (1.978 – 2.058)

Hydrophilic IOL Group

Preoperative

1.526 ± 0.18 (1.456 – 1.596)

< 0.01

Postoperative

1.976 ± 0.12 (1.936 – 2.016)

Figure 2

Contrast sensitivity function after phacoemulsification and Hydrophilic Intraocular lens implantation

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/619b310d-7b4e-48cf-ab7a-de47b2c7b0fe/image/90209fbe-58f3-416f-8fd7-af4b71dd852b-uimage.png

Figure 3

Contrast sensitivity function after phacoemulsification and Hydrophobic Intraocular lens implantation

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/619b310d-7b4e-48cf-ab7a-de47b2c7b0fe/image/84b04d9c-562a-4757-a064-abdf8a840254-uimage.png

At 12 weeks postoperative period, 25 patients who received hydrophobic intraocular lens and the other 25 patients who received hydrophilic intraocular lens had a mean contrast sensitivity of 2.018 ± 0.12 and 1.976 ± 0.12 respectively. An independent sample t-test was performed to assess the data between groups, indicating no statistically significant difference. (P value = 0.21) between the two groups (Table 5) (Figure 4).

Table 5

Comparison ofcontrast sensitivity function between hydrophilic and hydrophobic posterior chamber intraocular lens

Contrast Sensitivity function in postoperative group

Mean± Standard deviation (95% confidence interval)

P Value

Hydrophilic IOL group

1.976 ± 0.12 (1.936-2.016)

0.21

Hydrophobic IOL group

2.018 ± 0.11 (1.978 – 2.058)

Figure 4

Postoperative comparison of contrast sensitivity function between hydrophilic and hydrophobic Intraocular lens

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/619b310d-7b4e-48cf-ab7a-de47b2c7b0fe/image/d963f162-2ddd-4608-8b08-7fccb8e12839-uimage.png

Discussion

The current study sought to compare the enhancement of contrast sensitivity function following phacoemulsification, utilising either hydrophobic or hydrophilic posterior chamber intraocular lenses (PCIOLs).

Cataract surgery with PCIOL Implantation generally results in improved contrast sensitivity in patients with significant cataract. The Abbe number assesses the chromatic dispersion of optical materials, where higher values indicate lower chromatic dispersion and superior optical quality.14 Hydrophobic intraocular lenses (IOLs) exhibit lower Abbe numbers compared to hydrophilic IOLs, leading to greater chromatic dispersion and increased chromatic aberration in hydrophobic IOL materials.

Hygroscopy refers to a material's capacity to absorb and retain water. An elevation in hygroscopy diminishes the typical postoperative occurrence of glistenings – tiny fluid-filled micro vacuoles that emerge following intraocular lens (IOL) implantation. This is likely due to water entering the material, interacting with hydrophilic groups and preventing the accumulation in micro vacuoles.15

IOLs with high water content, characteristic of hydrophilic lenses, offer enhanced biocompatibility and reduced incidence of glare. Unfortunately, glistening's commonly affect hydrophobic IOLs. This study shows that the chromatic dispersion, glare disability and glistening’s due to lens material have no effect on the contrast sensitivity function.

The result of the study revealed that the contrast sensitivity improvement in patients is observed following cataract surgery, regardless of the intraocular lens material used.

Anthony Chang et al.'s 16 study concluded that over a span of 9 years, the hydrophobic intraocular lens (IOL) exhibited a higher occurrence of glistenings compared to the hydrophilic IOL. However, these glistenings did not impact Corrected Distance Visual Acuity (CDVA) or contrast sensitivity.

According to a study conducted by Akman A et al17 on glare disability in patients with hydrophilic and hydrophobic acrylic intraocular lens implants, it was concluded that eyes with hydrophilic acrylic IOL demonstrated superior results in glare disability compared to those with hydrophobic acrylic IOL. However, there was no significant difference between the two groups in terms of log contrast sensitivity values.

Aging has been shown to affect the contrast sensitivity18 but most of the subjects in this study were in the age group of 51 – 60 years (56%) and this might have not affected the results of this study. Only normal healthy subjects were enrolled in this study and patient with any ocular pathology or surgical complications which would have probably altered the contrast sensitivity function were not considered in this study.

Limitations

A primary limitation of our study was the relatively short three-month postoperative follow-up period. Extending the duration of follow-up would have provided additional valuable insights. More sophisticated methods are available to test contrast sensitivity function than Pelli Robson chart and contrast sensitivity under mesopic conditions was not measured in this study. Assessing the contrast sensitivity function under varied lighting conditions and utilizing advanced equipment could lead to a more comprehensive functional evaluation.

Conclusion

To conclude, contrast sensitivity is an indicator of the visual quality. In our study, in both hydrophilic and hydrophobic groups, contrast sensitivity function showed similar improvement and no statistically significant difference was observed between the groups. Our study shows that optical properties and the material of IOL has no impact on the contrast sensitivity. It is crucial to highlight that our follow-up period was limited to three months, emphasising the necessity for a long-term follow-up to thoroughly evaluate the impact of intraocular lens material on contrast sensitivity.

Source of Funding

Nil.

Conflicts of Interest

Nil.

References

1 

E Mela S Gartaganis J Koliopoulos Contrast sensitivity function after cataract extraction and intraocular lens implantationDoc Ophthalmol1996927991

2 

A Stalin K Dalton Relationship of Contrast Sensitivity Measured Using Quick Contrast Sensitivity Function With Other Visual Functions in a Low Vision PopulationInvest Ophthalmol Vis Sci202061621

3 

DC O'Carroll SD Wiederman Contrast sensitivity and the detection of moving patterns and featuresPhilos Trans R Soc Lond B Biol Sci1636369163620130043

4 

BA Sabel J Wang L Cárdenas-Morales M Faiq C Heim Mental stress as consequence and cause of vision loss: the dawn of psychosomatic ophthalmology for preventive and personalized medicineEPMA J20189213360

5 

M Murugappan J Vayalil A Bade Reliability of quick contrast sensitivity function testing in adults without ocular disease and patients with retinitis pigmentosaInvest Ophthalmol Vis Sci20165712616

6 

SA Haymes AW Johnston AD Heyes Relationship between vision impairment and ability to perform activities of daily livingOphthalmic Physiol Opt20022227991

7 

J Richman LL Lorenzana D Lankaranian J Dugar JR Mayer SS Wizov Relationships in glaucoma patients between standard vision tests, quality of life, and ability to perform daily activitiesOphthalmic Epidemiol201017314451

8 

CR Bennett PJ Bex CM Bauer L B Merabet The Assessment of Visual Function and Functional VisionSemin Pediatr Neurol2019313040

9 

A Arditi Improving the design of the letter contrast sensitivity testInvest Ophthalmol Vis Sci200546622259

10 

AK Kiser D Mladenovich F Eshraghi D Bourdeau G Dagnelie Reliability and consistency of visual acuity and contrast sensitivity measures in advanced eye diseaseOptom Vis Sci2005821194654

11 

M Mahjoob AJ Anderson Contrast discrimination under task-induced mental loadVision Res2019165849

12 

DB Elliott K Sanderson A Conkey The reliability of the PelliRobson contrast sensitivity chartOphthalmic Physiol Opt1990101214

13 

M Mäntyjärvi T Laitinen Normal values for the PelliRobson contrast sensitivity testJ Cataract Refract Surg20012722616

14 

H Zhao MA Mainster The effect of chromatic dispersion on pseudophakic optical performanceBr J Ophthalmol200791912259

15 

TM Yildirim H Fang SK Schickhardt Q Wang PR Merz GU Auffarth Glistening formation in a new hydrophobic acrylic intraocular lensBMC Ophthalmol2020201186

16 

A Chang M Kugelberg Glistenings 9 years after phacoemulsification in hydrophobic and hydrophilic acrylic intraocular lensesJ Cataract Refract Surg20154161199204

17 

A Akman S Bozbeyoglu YA Akova Glare disability in patients with hydrophilic and hydrophobic acrylic intraocular lens implantsEur J Ophthalmol2004141148

18 

A Hawkins J Szlyk Z Ardickas K Alexander J Wilensky Comparison of Contrast Sensitivity, Visual Acuity, and Humphrey Visual Field Testing in Patients with GlaucomaJ Glaucoma20031221348



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Article type

Original Article


Article page

275-280


Authors Details

Narasimha Rao V L Mukkamala, Sumalatha Sai Keerthi Mathukumalli*, Vivekanand Undrakonda, Pradeep Pakalapati


Article History

Received : 19-01-2024

Accepted : 05-03-2024


Article Metrics


View Article As

 


Downlaod Files