Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Original Article


Article page

376- 381


Authors Details

Mohan Kumar H, Sangeetha T, Kanthamani , Nithiya Joe Babu*


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1650

PDF Downloaded: 507


Comparison of accuracy of haigis and SRK II formula for intraocular lens power calculation in eyes with short axial length


Original Article

Author Details : Mohan Kumar H, Sangeetha T, Kanthamani , Nithiya Joe Babu*

Volume : 5, Issue : 3, Year : 2019

Article Page : 376-381

https://doi.org/10.18231/j.ijceo.2019.090



Suggest article by email

Get Permission

Abstract

Introduction: This study aimed to measure the postoperative residual spherical error and to find the correlation between the axial length and anterior chamber depth measured preoperatively with the postoperative refractive status.
Materials and Methods: A total of 174 patients of the age group 40-70 years axial length ? 22 mm undergoing cataract surgery were included in our prospective study in which the accuracy of SRK II was compared with Haigis formula. The participants were divided into group A and B by simple randomization technique. The subjects under group A were implanted with IOL calculated using Haigis formula and those under group B with SRK II formula. They were evaluated for visual acuity and residual refractive error. The degree of emmetropia of the participants was analysed using above data.
Results: A total of 174 eyes were included in our study of which 64 (36.7%) were males and 110(63.2%) were females. The mean axial length was 21.47mm and the mean anterior chamber depth was 3.17mm. Significant differences were found between the spherical error calculated by SRK II formula and Haigis formula. The mean spherical error in group A with Haigis formula was - 0.36 (range 0 D to -1.5) meanwhile group B with SRK II formula had a mean spherical error of + 0.55 (range 0 to +2 D). The postoperative refraction of patients implanted with IOLs calculated using Haigis formula was closer to emmetropia.
Conclusion: It was found that in patients with short axial length, Haigis formula gave an accurate prediction of the IOL power compared to SRK II formula. Using Haigis formula led to a mild over correction leading to a slightly more myopic outcome while SRK II formula led to a mild under correction leading to a mild hypermetropic outcome.

Keywords: Formula, Haigis, IOL power calculations, SRK II, Short axial length.


How to cite : Mohan Kumar H, Sangeetha T, Kanthamani, Babu N J, Comparison of accuracy of haigis and SRK II formula for intraocular lens power calculation in eyes with short axial length. Indian J Clin Exp Ophthalmol 2019;5(3):376-381

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.