Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Original Article


Article page

130- 136


Authors Details

Sameera Irfan


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 3012

PDF Downloaded: 477



Original Article

Author Details : Sameera Irfan

Volume : 1, Issue : 3, Year : 2015

Article Page : 130-136


Suggest article by email

Get Permission

Abstract

Purpose: To find out how effective and safe Trans-ciliary Filtration with a Fugo-Plasma Blade is in providing a long term IOP control in different varieties of Glaucoma.

Material and Methods: A prospective interventional study was conducted at a tertiary care centre from Jan 2013 till July 2015. Trans-ciliary Filtration by Fugo Plasma Blade was performed by a single surgeon (SI) on 52 consecutive eyes from age 6 months to 55 years. All cases were referred because IOP was uncontrolled on triple anti-glaucoma medication .The mean follow-up after TCF was 1 year.
Results: In 48 eyes, IOP remained below 15 mm without the addition of any anti-glaucoma medication up to 1 year follow-up. This was a success rate of 80.76%. In 2 eyes with neovascular glaucoma, the bleb failed due to neo-vascularization and Cycle-Cryotherapy had to be performed. In 2 eyes with Buphthalmos, the IOP gradually crept up to 22 mm and they needed the addition of topical beta blocker drug.
Conclusion: TCF performed with the Fugo Plasma blade is a safe procedure with minimal complications, easy to learn and master and offers efficient long-term IOP control in various types of glaucoma except the neo-vascular.
 
Key words: Trans-ciliary Filtration, Glaucoma surgery, Trabeculectomy, Fugo-plasma Blade, Conjunctival lymphatics.


How to cite : Irfan S, . Indian J Clin Exp Ophthalmol 2015;1(3):130-136

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.