Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Null


Article page

118- 120


Authors Details

Chaitra Pujar, Shivakumar Hiremath*, Vidya Rudrappa Gadag


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1316

PDF Downloaded: 479


Correlations between tear function abnormalities and pseudoexfoliation: A comparative study


Null

Author Details : Chaitra Pujar, Shivakumar Hiremath*, Vidya Rudrappa Gadag

Volume : 5, Issue : 1, Year : 2019

Article Page : 118-120

https://doi.org/10.18231/2395-1451.2019.0028



Suggest article by email

Get Permission

Abstract

Aim: Pseudoexfoliation (PEX) could alter the tear secretion and unstabilize it by modifying the cell morphology in conjunctiva. Abnormalities of tear secretion and tear film have been assessed that can occur in eyes with PEX syndrome as compared to normal eyes.
Materials and Methods: A prospective non-randomized study consisting of Group 1 with 60 eyes of 30 normal subjects without PEX material on lens as controls and Group 2 with 60 eyes of 30 patients with PEX material in both eyes as cases were taken. Exclusion criteria included patients with ocular surface disorders, PEX glaucoma, previous ocular surgeries, long term use of eye drops and adnexal abnormalities. Tear functions were assessed by, Schirmer’s 2 test and tear break-up time (TBUT).
Results: The mean age in group 1 was 64 years and group 2 was 62 years. There were 14 males and 16 females in group 1 whereas 20 males and 10 females in group 2. Average of Schirmer’s and TBUT in group 1 were 24.02mm and 15.65s respectively, whereas in Group 2 they were 11.6mm and 7.8s and difference was clinically significant. Among the eyes with PEX, 54.2%of cases had PEX material in both zone 1 and zone 3. 30.8% of cases had only in zone 1 and 15% had only in zone 3.Hence 69.2% of cases had PEX material in zone 3. The average mydriasis in eyes with PEX was 5.2 and in eyes without PEX was 6.5.
Conclusion: PEX syndrome alters tear film stability and decreases tear secretion.

Keywords: Dry eye, Pseudoexfoliation, Schirmer’s test, Tear function.


How to cite : Pujar C, Hiremath S, Gadag V R, Correlations between tear function abnormalities and pseudoexfoliation: A comparative study. Indian J Clin Exp Ophthalmol 2019;5(1):118-120

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.