Print ISSN: 2395-1443
Online ISSN: 2395-1451
CODEN : IJCEKF
Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...Null
Author Details :
Volume : 5, Issue : 1, Year : 2019
Article Page : 66-70
https://doi.org/10.18231/2395-1451.2019.0016
Abstract
Purpose: To evaluate the angle of anterior chamber with SD-OCT in patients above 40 years of age presenting to tertiary health care center in central India.
Materials and Methods: 120 Consecutive patients (240 eyes) above 40 years of age presenting to ophthalmology OPD of tertiary health care center were enrolled in a cross-sectional study. All patients underwent comprehensive ocular examination with included best corrected visual acuity, slit lamp, fundus, gonioscopy, intraocular pressure (IOP), evaluation of angle (i.e. AOD, TISA, TIA) of anterior chamber with SD-OCT. The duration of study was one year six months.
Result: The mean age was 53.94 years. There were 61 males & 59 females. It was noted that mean nasal & temporal AOD was less in females (0.4175 µm, 0.4142 µm) as compared to males (0.4583 µm, 0.4613 µm). We found that older people have a narrower anterior chamber angle i.e. from 40-60 years of age mean TIA nasal & temporal was 29.13, 27.53 degree & above 60 years of age mean TIA nasal & temporal was-24.13, 22.63 degrees.
Conclusion: We found that AOD is less in female as compared to male. It was also noted that older people have a narrower anterior chamber angle as compared to younger people. The gonioscopy has been considered as the gold standard for characterizing the ACA, but it is contact procedure, subjective and requires the expertise while the OCT is rapid, quantitative, reproducibility, non-contact procedure with less interobserver variability will help us to accurately assess anterior chamber angle.
Keywords: Anterior chamber angle measurement, Gonioscopy, Narrow angle, SD-OCT, Normal population.
How to cite : Khan N, Gupta S, Agrawal P, Assessment of angle of anterior chamber with SD-OCT in patients presenting to tertiary health care center. Indian J Clin Exp Ophthalmol 2019;5(1):66-70
This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.