Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Original Article


Article page

419-421


Authors Details

Monika Kharbanda, Ishwar Singh, Sachin Walia, Harsimran Singh


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1235

PDF Downloaded: 416


Evaluation of changes in IOP and anterior chamber parameters post laser irodotomy using pentacam system


Original Article

Author Details : Monika Kharbanda, Ishwar Singh, Sachin Walia, Harsimran Singh

Volume : 3, Issue : 4, Year : 2017

Article Page : 419-421


Suggest article by email

Get Permission

Abstract

Introduction: Aim of the study was to evaluate IOP changes and anterior chamber parameters (depth and volume), in primary angle closure (PAC) cases after laser peripheral irodotomy (LPI) using Pentacam system in OPD patients at Govt. Medical College, Patiala.
Material and Methods: Total 12 eyes of 12 PAC patients were analysed in the study in the period of 3 months from March 2017 to May 2017. LPI was performed on the enrolled eyes, Pentacam system was used to calculate anterior chamber and IOP changes pre and post 14 days of LPI treatment.
Results: There was statistically significant difference before LPI and after LPI for all measured variables. The mean ACD and ACV increased by p=0.04 and p = 0.001 respectively in 12 patients. The mean IOP decreased in all eyes with p=0.03 at month 3 and thereafter.
Conclusion: In conclusion, LPI produces significant anterior chamber depth & volume along with decrease in IOP making LPI effective in treatment of primary angle closure cases.

Keywords: IOP, Pentacam, LPI, Primary Angle closure

 


How to cite : Kharbanda M, Singh I, Walia S, Singh H, Evaluation of changes in IOP and anterior chamber parameters post laser irodotomy using pentacam system. Indian J Clin Exp Ophthalmol 2017;3(4):419-421

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.