Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Original Article


Article page

-


Authors Details

Jyothi P., Sandhya S., Bindu


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1294

PDF Downloaded: 445


Inter ocular variability of common glaucoma parameters in patients with primary open angle glaucoma


Original Article

Author Details : Jyothi P., Sandhya S., Bindu

Volume : 3, Issue : 4, Year : 2017

Article Page : -


Suggest article by email

Get Permission

Abstract

Aim: To assess the intrasubject variability of CCT,IOP and VCDR in patients with POAG compared to normal.
Design: Cross sectional study.
Materials and Methods: A total of 100 eyes of patients on treatment for POAG and 100 eyes of normal individuals were included in the study. All patients underwent a complete ophthalmological examination including CCT corrected IOP, visual field by HFA and disc evaluation using 90D assisted slit lamp biomicroscopy. CCT was measured using ultrasonic pachymetry in all of them. The difference in IOP, Vertical CD ratio and CCT were compared between the two eyes in POAG patients and in normal individuals.
Results: The mean difference in IOP was 3.52±3.8 in POAG group compared to 1.06±0.9 in normal .The mean difference in CD ratio was 0.132±0.15 in POAG compared to 0.05±0.07 in normal. The mean difference in CCT was also significantly higher in POAG patients. [8.10±7.4] when compared to normal individuals [5.05±5.17].

Keywords: Central Corneal Thickness, Intraocular pressure, Inter ocular variability, Vertical cup disc ratio


How to cite : Jyothi P., Sandhya S., Bindu, Inter ocular variability of common glaucoma parameters in patients with primary open angle glaucoma. Indian J Clin Exp Ophthalmol 2017;3(4):-

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.