Indian Journal of Clinical and Experimental Ophthalmology

Print ISSN: 2395-1443

Online ISSN: 2395-1451

CODEN : IJCEKF

Indian Journal of Clinical and Experimental Ophthalmology (IJCEO) is open access, a peer-reviewed medical journal, published quarterly, online, and in print, by the Innovative Education and Scientific Research Foundation (IESRF) since 2015. To fulfil our aim of rapid dissemination of knowledge, we publish articles ‘Ahead of Print’ on acceptance. In addition, the journal allows free access (Open Access) to its content, which is likely to attract more readers and citations of articles published in IJCEO. Manuscripts must be prepared in more...

Article type

Original Article


Article page

426- 431


Authors Details

Chidanand Kulkarni, Rajashekar Mohan Metri*


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1217

PDF Downloaded: 930


Comparison of nuclear size in mature and hypermature cataract


Original Article

Author Details : Chidanand Kulkarni, Rajashekar Mohan Metri*

Volume : 5, Issue : 4, Year : 2019

Article Page : 426-431

https://doi.org/10.18231/j.ijceo.2019.103



Suggest article by email

Get Permission

Abstract

Introduction: Senile white cataracts are special cases in cataract surgery since they are associated with
unique set of complications not seen in immature cataracts. The major drawback while operating on a white
cataract is lack of nuclear details like its density or size. This study was conducted to establish nuclear size
in mature and hypermature senile cataracts.
Materials and Methods: The study involved intact nucleus obtained during manual small incision cataract
surgery. The cases were grouped into mature or hypermature category. The nucleus was measured directly
using electronic scale on a smartphone calibrated to measure up to 10 micrometers. The thickness and
diameter of nucleus were recorded. These values and ocular parameters obtained by immersion A-scan
preoperatively were analyzed.
Results: The mean nuclear thickness in mature cataracts was 3.66 mm (3.17 to 4.38) and in hypermature
cataracts was 3.36 mm (2.66 to 3.95). There was significant difference in nuclear thickness and lens
thickness between the two groups. The nuclear diameter did not vary significantly between the two groups.
Conclusion: The nucleus in mature cataract is significantly thicker than that of hypermature cataract
and occupies most of the lens volume indicating a dense nucleus. During phacoemulsification of mature
cataract, it is advisable to increase the machine parameters to tackle this dense nucleus. While in case of
hypermature cataract the machine parameters should be lowered as, the nucleus is thinner and less dense.

Keywords: Mature cataract, Hypermature cataract, White cataract, Nuclear thickness, Nuclear diameter.


How to cite : Kulkarni C, Metri R M, Comparison of nuclear size in mature and hypermature cataract. Indian J Clin Exp Ophthalmol 2019;5(4):426-431

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.